{"id":1392,"date":"2019-12-22T21:28:35","date_gmt":"2019-12-22T14:28:35","guid":{"rendered":"http:\/\/hieuchuan3d.com\/?post_type=product&#038;p=1392"},"modified":"2019-12-22T21:28:36","modified_gmt":"2019-12-22T14:28:36","slug":"kinh-hien-vi-do-luong-may-do-luong-olympus-stm6","status":"publish","type":"product","link":"https:\/\/backup.hieuchuan3d.com\/en\/san-pham\/kinh-hien-vi-do-luong-may-do-luong-olympus-stm6\/","title":{"rendered":"(Ti\u1ebfng Vi\u1ec7t) K\u00ednh hi\u1ec3n vi \u0111o l\u01b0\u1eddng &#8211; M\u00e1y \u0111o l\u01b0\u1eddng Olympus STM6"},"content":{"rendered":"<p class=\"qtranxs-available-languages-message qtranxs-available-languages-message-en\">Sorry, this entry is only available in <a href=\"https:\/\/backup.hieuchuan3d.com\/vi\/wp-json\/wp\/v2\/product\/1392\" class=\"qtranxs-available-language-link qtranxs-available-language-link-vi\" title=\"Ti\u1ebfng Vi\u1ec7t\">Vietnamese<\/a>. For the sake of viewer convenience, the content is shown below in the alternative language. You may click the link to switch the active language.<\/p><p><\/p>\n<h2>Space-saving Design\/ High-accuracy Stages to Meet Customer Requirements<\/h2>\n<hr \/>\n<h3>Small Footprint<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_space_saving_design_diagram.jpg?rev=A34D\" alt=\"STM6 Space-saving Design diagram\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Space-saving Design<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">This model has a space-saving, compact design while retaining the various functions required in today&#8217;s environment. (295mm in width and 429.4mm in depth).<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Four Different Optional Stages<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><a class=\"imageResizerZoom iPop\" href=\"https:\/\/static1.olympus-ims.com\/modules\/imageresizer\/9fb\/dd3\/9a95b6511b\/250x188p125x94.gif\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/static1.olympus-ims.com\/modules\/imageresizer\/9fb\/dd3\/9a95b6511b\/250x188p125x94.gif\" alt=\"STM6 Coarse\/Fine-feed Coaxial Wheel\" width=\"250\" height=\"188\" \/><\/a><br \/>\n<span class=\"smallCaption\">Coarse\/Fine-feed Coaxial Wheel<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">One of four types of stages can be selected according to your requirements. Three of the stages (50&#215;50, 100&#215;50, and 100&#215;100) employ a coarse\/fine coaxial wheel while the 150&#215;100 stage employs a clutch-free mechanism, achieving quick displacement and fine positioning.<\/div>\n<\/div>\n<\/div>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_stage_MM6C-CS150_150x100.jpg?rev=8D2F\" alt=\"MM6C-CS150 (150x100 Table)\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">MM6C-CS150 (150&#215;100 Table)<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_stage_MM6C-CS100_100x100.jpg?rev=C8F9\" alt=\"MM6C-CS100 (100x100 Table)\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">MM6C-CS100 (100&#215;100 Table)<\/span><\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static5.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_stage_MM6C-CS100R_100x50.jpg?rev=720C\" alt=\"MM6C-CS100R (100x50 Table)\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">MM6C-CS100R (100&#215;50 Table)<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static1.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_stage_MM6C-CS50_50x100.jpg?rev=3E8B\" alt=\"MM6C-CS50 (50x50 Table)\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">MM6C-CS50 (50&#215;50 Table)<\/span><\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h2><a id=\"02\" name=\"02\"><\/a>High Measuring Accuracy and Durability<\/h2>\n<hr \/>\n<h3>High-rigidity Body and Stage Resistant to Atmospheric Changes<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_FEM_analysis_body.jpg?rev=6CFB\" alt=\"STM6 FEM Analysis of microscope body\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">FEM Analysis<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">Maintaining accuracy is of paramount importance in any measuring instrument. In addition, retaining rigidity over long periods of time is crucial for reproducible measurements. Olympus has developed a high-rigidity body and precise stages that are resistant to atmospheric changes. The adoption of a linear guide mechanism and the incorporation of an original linear scale allows Olympus to meet the measurement needs of client with high reliability.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Optical Linear Scale that Provides Sub-micron Resolution<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_optical_linear_scale.jpg?rev=6F6E\" alt=\"STM6 Optical Linear Scale\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Optical Linear Scale<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">Scale accuracy is a key point to determine the accuracy of a measuring microscope. The STM6 electrically processes and measures the optical information obtained through Olympus&#8217; optical linear scale.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Traceability System to International Standards<\/h3>\n<p>Olympus maintains the highest-level environment throughout the stages of production and assembly to ensure high precision. At our temperature-controlled plant, skilled Olympus engineers perform high-precision machining of carefully selected component materials, delicate finishing processes and final adjustments. All component parts and completed products are fully controlled under a rigorous traceability system.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_measuring_microscopes_traceability_system_chart.gif?rev=735E\" alt=\"Measuring Microscopes Traceability System Chart\" width=\"525\" height=\"383\" \/><br \/>\n<span class=\"smallCaption\">Measuring Microscopes Traceability System<\/span><\/p>\n<hr \/>\n<h2><a id=\"03\" name=\"03\"><\/a>The STM6 was Designed with Emphasis on Ease of Use<\/h2>\n<hr \/>\n<h3>Motorized Focus Unit Available for Quick Z-axis Measurement<\/h3>\n<p>The STM6 has adopted a motorized focus unit that significantly improves operability when focusing and measuring a height or depth. 5 step control over the speed of the vertical Z motor, greatly reduces fatigue during operation.<\/p>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_z-axis_control_box.jpg?rev=D4BE\" alt=\"Z-axis Control Box\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Z-axis Control Box<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><\/p>\n<ol>\n<li>Motorizedocusing Button<\/li>\n<li>Auto Focus Button<\/li>\n<li>Set-up Button for Upper and Lower Limits<\/li>\n<li>Auto Focus Stop Button<\/li>\n<li>Z Reset Button<\/li>\n<li>Focusing Handle<\/li>\n<li>Data Output Button<\/li>\n<li>Coarse and Fine Switchover Button<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Counter Located at the Ideal Observation Position<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static1.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_integrated_counter.jpg?rev=1B2C\" alt=\"STM6 Integrated Counter\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Counter<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">The integrated counter is mounted on the microscope body, with the display unit located a eye-level for simple observation. The operator can thereby confirm a measuring value with only a slight movement of the eye, allowing concentration on the specimen under observation.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>UIS2 Optical System and LED Illumination Enhances Edge Detection<\/h3>\n<p>The STM6 employs Olympus&#8217; UIS2 optical system that achieves superior resolution and contrast, and LED illumination that delivers faithful color reproduction independent of changes in brightness. This greatly improves the detection of edges, thus resulting in dramatic improvement in measurement repeatability. The LED illumination is also free from flickering and brightness fluctuation, reducing eye fatigue even over extended periods of operation.<\/p>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_white_LED_illumination_example.jpg?rev=D5F6\" alt=\"White LED Illumination Example\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">White LED<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_halogen_illumination_example.jpg?rev=79A4\" alt=\"Halogen Lamp Illumination Example\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Halogen Lamp<\/span><\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Reticles are Used for Easy Positioning<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static3.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_alignment_reticles.jpg?rev=9C18\" alt=\"Reticle\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Reticle<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">Accurate alignment between the object being measured and the reticle is critical to any measuring microscope. In straight-line alignment, the use of a reticle and a dotted line will produce more accurate results than using a single line. Olympus has further improved alignment accuracy by using a reticle and a dotted line on the focusing plate.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h2><a id=\"04\" name=\"04\"><\/a>Automated Focusing System Provides Superior Repeatability<\/h2>\n<hr \/>\n<h3>High-accuracy Auto Focus System (available as an option)<\/h3>\n<p>This laser-based focus system provides two modes of functions: one-shot and trace. Visual measurement of a height or a depth, which requires subtle operations, can be automated by selecting either mode. This significantly improves the efficiency and reproducibility of Z-axis measurements while allowing continued observation while using both hands on the stage control knobs.<\/p>\n<p><strong>[One-Shot Mode]<\/strong><br \/>\nThis mode provides instant focusing in the center of the field of view through the execution of the auto focus.<\/p>\n<p><strong>[Trace Mode]<\/strong><br \/>\nThis mode always maintains the state in focus while moving the stage across a sample. This greatly improves the operating time.<\/p>\n<div class=\"table-responsive\">\n<table class=\"list1 nowrap default-scrolling\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"3\">List of Auto Focus Performance for Each Objective Lens<\/td>\n<\/tr>\n<tr>\n<td>Objective Lens<\/td>\n<td>Repeatability(2\u03c3n-1)*1<\/td>\n<td>Spot diameter *2<\/td>\n<\/tr>\n<tr>\n<td>LMPLFLN20x<\/td>\n<td>2\u00b5m<\/td>\n<td>\u00f85\u00b5m<\/td>\n<\/tr>\n<tr>\n<td>LMPLFLN50x<\/td>\n<td>1\u00b5m<\/td>\n<td>\u00f82\u00b5m<\/td>\n<\/tr>\n<tr>\n<td>LMPLFLN100x<\/td>\n<td>1\u00b5m<\/td>\n<td>\u00f81\u00b5m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>*1 : Indicates a value based on Olympus reference specimen.<br \/>\n*2 : Indicates a theoretical value by calculation.<\/p>\n<hr \/>\n<h3>Focus Navigator Achieves High-accuracy Height Measurement and Increased Reproducibility<\/h3>\n<p>Olympus Focus Navigator system improves reproducibility during focusing by aligning the vertical displacement of the index pattern projected on the specimen. The focus navigator improves the repeatability in height measurement and reduces measurement variations due to personal difference, compared with visual focusing. The index pattern is compatible with various specimens simplifying focusing to contribute a dramatic reduction in measurement time. The Focus Navigator unit is compatible with reflected brightfield and reflected darkfield observations with objective lenses of 10x through 50x.<\/p>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-12\n\t\t\t\tcol-sm-12 \"><strong>Focus Navigator Alignment Image<\/strong><\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-4\n\t\t\t\tcol-sm-4 \"><img decoding=\"async\" src=\"https:\/\/static5.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_focus_point_front.jpg?rev=A173\" alt=\"Focus Point on the Front Side\" width=\"170\" height=\"160\" \/><br \/>\n<span class=\"smallCaption\">Focus Point on the Front Side<\/span><\/div>\n<div class=\"col-lg-4\n\t\t\t\tcol-sm-4 \"><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_focus_point_in_place.jpg?rev=F729\" alt=\"Focus Point Just in Place\" width=\"195\" height=\"160\" \/><br \/>\n<span class=\"smallCaption\">Focus Point Just in Place<\/span><\/div>\n<div class=\"col-lg-4\n\t\t\t\tcol-sm-4 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_focus_point_rear.jpg?rev=ABE4\" alt=\"Focus Point on the Rear Side\" width=\"170\" height=\"160\" \/><br \/>\n<span class=\"smallCaption\">Focus Point on the Rear Side<\/span><\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h2><a id=\"05\" name=\"05\"><\/a>Accessories that Widen the Range of Observation and Measurement<\/h2>\n<hr \/>\n<h3>Reflected Illumination Units<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static3.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_reflected_illumination_units.jpg?rev=B95E\" alt=\"Reflected Illumination Units\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Reflected Illumination Units<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">Three types of reflected illumination units are available to support a variety of measuring ranges. These illumination units are capable of brightfield, darkfield, or differential interference contrast observation, corresponding to measuring objective lenses or metallurgical objective lenses with a revolving nosepiece.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Rotary Table<\/h3>\n<p>This table can perform leveling of a specimen with ease.<\/p>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_MM6C-RS2_rotatable_stage.jpg?rev=8118\" alt=\"MM6C-RS2 rotatable stage, type 2\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">MM6C-RS2 rotatable stage, type 2<br \/>\n(For MM6C-CS150)<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static3.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_MM6C-RS1_rotatable_stage.jpg?rev=AC9A\" alt=\"MM6C-RS1 rotatable stage, type 1\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">MM6C-RS1 rotatable stage, type 1<br \/>\n(For MM6C-CS100R and MM6C-CS100)<\/span><\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>White LED Illumination Unit<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static4.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_white_LED_illuminaton_unit.jpg?rev=CC05\" alt=\"White LED Illumination Unit\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">Rotary Table<br \/>\n*The model of the LED illuminator may vary with area.<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">This white LED light source unit features a long service life, power savings, a reduction in size and weight, and high performance with no flickering or brightness fluctuation.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>4-divided LED Illumination Unit<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static2.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_4_divided_white_LED_illuminaton_unit.jpg?rev=9B9D\" alt=\"4-divided LED Illumination Unit\" width=\"250\" height=\"188\" \/><br \/>\n<span class=\"smallCaption\">4-divided LED Illumination Unit<\/span><\/div>\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \">This reflected LED ring-light illuminator provides high color temperature and clear images. This unit provides 4-divided independent illumination and allows you to select an optimal illumination mode from among a total of 13 patterns.<\/div>\n<\/div>\n<\/div>\n<hr \/>\n<h3>Recording and Storage of Digital Images is Possible with a Digital Camera.<\/h3>\n<p>A digital camera can be attached to the STM6&#8217;s trinocular tube. This allows recording and storage of digital images, facilitating report generation. Choose from Olympus&#8217; wide range of digital cameras based on your application in terms of image quality, functions, and operability.<\/p>\n<h2>System for Achieving More Advanced Measurement<\/h2>\n<hr \/>\n<h3>Arithmetic Device Equipped with Versatile Functions<\/h3>\n<div class=\"formerTable\">\n<div class=\"row\">\n<div class=\"col-lg-6\n\t\t\t\tcol-sm-6 \"><img decoding=\"async\" src=\"https:\/\/static5.olympus-ims.com\/data\/Image\/IM\/measuring\/STM6_geometric_calculator_MM-CAL22.jpg?rev=1F24\" alt=\"Geometric Calculator MM-CAL22\" width=\"250\" height=\"188\" border=\"0\" \/><br \/>\n<span class=\"smallCaption\">Geometric Calculator MM-CAL22<br \/>\n*MM6-CAL22 may not be available in some area.<\/span><\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Sorry, this entry is only available in Vietnamese. For the sake of viewer convenience, the content is shown below in the alternative language. You may click the link to switch the active language. Space-saving Design\/ High-accuracy Stages to Meet Customer Requirements Small Footprint Space-saving Design This model has a space-saving, compact design while retaining the [&hellip;]<\/p>\n","protected":false},"featured_media":1393,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[728],"product_tag":[755,756,753,757,754],"acf":[],"_links":{"self":[{"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/product\/1392"}],"collection":[{"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/comments?post=1392"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/media\/1393"}],"wp:attachment":[{"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/media?parent=1392"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/product_cat?post=1392"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/backup.hieuchuan3d.com\/en\/wp-json\/wp\/v2\/product_tag?post=1392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}