Mô tả
Space-saving Design/ High-accuracy Stages to Meet Customer Requirements
Small Footprint

Space-saving Design
Four Different Optional Stages

MM6C-CS150 (150×100 Table)

MM6C-CS100 (100×100 Table)

MM6C-CS100R (100×50 Table)

MM6C-CS50 (50×50 Table)
High Measuring Accuracy and Durability
High-rigidity Body and Stage Resistant to Atmospheric Changes

FEM Analysis
Optical Linear Scale that Provides Sub-micron Resolution

Optical Linear Scale
Traceability System to International Standards
Olympus maintains the highest-level environment throughout the stages of production and assembly to ensure high precision. At our temperature-controlled plant, skilled Olympus engineers perform high-precision machining of carefully selected component materials, delicate finishing processes and final adjustments. All component parts and completed products are fully controlled under a rigorous traceability system.

Measuring Microscopes Traceability System
The STM6 was Designed with Emphasis on Ease of Use
Motorized Focus Unit Available for Quick Z-axis Measurement
The STM6 has adopted a motorized focus unit that significantly improves operability when focusing and measuring a height or depth. 5 step control over the speed of the vertical Z motor, greatly reduces fatigue during operation.

Z-axis Control Box
- Motorizedocusing Button
- Auto Focus Button
- Set-up Button for Upper and Lower Limits
- Auto Focus Stop Button
- Z Reset Button
- Focusing Handle
- Data Output Button
- Coarse and Fine Switchover Button
Counter Located at the Ideal Observation Position

Counter
UIS2 Optical System and LED Illumination Enhances Edge Detection
The STM6 employs Olympus’ UIS2 optical system that achieves superior resolution and contrast, and LED illumination that delivers faithful color reproduction independent of changes in brightness. This greatly improves the detection of edges, thus resulting in dramatic improvement in measurement repeatability. The LED illumination is also free from flickering and brightness fluctuation, reducing eye fatigue even over extended periods of operation.

White LED

Halogen Lamp
Reticles are Used for Easy Positioning

Reticle
Automated Focusing System Provides Superior Repeatability
High-accuracy Auto Focus System (available as an option)
This laser-based focus system provides two modes of functions: one-shot and trace. Visual measurement of a height or a depth, which requires subtle operations, can be automated by selecting either mode. This significantly improves the efficiency and reproducibility of Z-axis measurements while allowing continued observation while using both hands on the stage control knobs.
[One-Shot Mode]
This mode provides instant focusing in the center of the field of view through the execution of the auto focus.
[Trace Mode]
This mode always maintains the state in focus while moving the stage across a sample. This greatly improves the operating time.
| List of Auto Focus Performance for Each Objective Lens | ||
| Objective Lens | Repeatability(2σn-1)*1 | Spot diameter *2 |
| LMPLFLN20x | 2µm | ø5µm |
| LMPLFLN50x | 1µm | ø2µm |
| LMPLFLN100x | 1µm | ø1µm |
*1 : Indicates a value based on Olympus reference specimen.
*2 : Indicates a theoretical value by calculation.
Focus Navigator Achieves High-accuracy Height Measurement and Increased Reproducibility
Olympus Focus Navigator system improves reproducibility during focusing by aligning the vertical displacement of the index pattern projected on the specimen. The focus navigator improves the repeatability in height measurement and reduces measurement variations due to personal difference, compared with visual focusing. The index pattern is compatible with various specimens simplifying focusing to contribute a dramatic reduction in measurement time. The Focus Navigator unit is compatible with reflected brightfield and reflected darkfield observations with objective lenses of 10x through 50x.

Focus Point on the Front Side

Focus Point Just in Place

Focus Point on the Rear Side
Accessories that Widen the Range of Observation and Measurement
Reflected Illumination Units

Reflected Illumination Units
Rotary Table
This table can perform leveling of a specimen with ease.

MM6C-RS2 rotatable stage, type 2
(For MM6C-CS150)

MM6C-RS1 rotatable stage, type 1
(For MM6C-CS100R and MM6C-CS100)
White LED Illumination Unit

Rotary Table
*The model of the LED illuminator may vary with area.
4-divided LED Illumination Unit

4-divided LED Illumination Unit
Recording and Storage of Digital Images is Possible with a Digital Camera.
A digital camera can be attached to the STM6’s trinocular tube. This allows recording and storage of digital images, facilitating report generation. Choose from Olympus’ wide range of digital cameras based on your application in terms of image quality, functions, and operability.
System for Achieving More Advanced Measurement
Arithmetic Device Equipped with Versatile Functions

Geometric Calculator MM-CAL22
*MM6-CAL22 may not be available in some area.